Hello,

I am trying to come up with a way to auto add new servers deployed with LSI raid cards to the MegaRaid Software management server. From the gui, it looks like I can add them by IP manually, or have the control server scan for hosts with the MegaRaid client software, which only works if the host is on the same network. Anybody ever work with this software and done something like this?

5 thoughts on - Automated LSI Card Management.

  • While that makes sense, I find the megacli utility to be a very poorly done program from a users perspective. The Management server would also be used for the alerts that it generates, and would save me the time of writing monitoring scripts.

  • I agree the CLI program isn’t very user friendly, but scripting it is actually pretty easy, and I would hardly consider the minor effort of writing a simple monitoring script to be reason for provisioning an entire server.

    Peter

  • i found and modified a python script that parses the output of megacli to create a useful status page in a format that could easily be then grepped for errors for an alert. I’ll try and dig it up after dinner.

  • k, here it is. I call this lsi-raidinfo and keep it in /root/bin as its only meant for root’s use. it assumes you’ve installed megacli.
    (note, there’s 2 more scripts following)

    #!/usr/bin/python

    # megaclisas-status 0.6
    # renamed lsi-raidinfo
    #
    # This program is free software; you can redistribute it and/or modify
    # it under the terms of the GNU General Public License as published by
    # the Free Software Foundation; either version 2 of the License, or
    # (at your option) any later version.
    #
    # This program is distributed in the hope that it will be useful,
    # but WITHOUT ANY WARRANTY; without even the implied warranty of
    # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
    # GNU General Public License for more details.
    #
    # You should have received a copy of the GNU General Public License
    # along with Pulse 2; if not, write to the Free Software
    # Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston,
    # MA 02110-1301, USA.
    #
    # Copyright (C) 2007-2009 Adam Cecile (Le_Vert)

    ## modified by johnpuskar@gmail.com 08/14/11
    # fixed for LSI 9285-8e on Openfiler

    ## modified by pierce@hogranch.com 2012-01-05
    # fixed for newer version of megacli output on RHEL6/CentOS6
    # output format extended to show raid span-unit and rebuild % complete

    import os import re import sys

    if len(sys.argv) > 2:
    print ‘Usage: lsi-raidinfo [-d]’
    sys.exit(1)

    # if argument -d, only print disk info printarray = True printcontroller = True if len(sys.argv) > 1:
    if sys.argv[1] == ‘-d’:
    printarray = False
    printcontroller = False
    else:
    print ‘Usage: lsi-raidinfo [-d]’
    sys.exit(1)

    # Get command output def getOutput(cmd):
    output = os.popen(cmd)
    lines = []
    for line in output:
    if not re.match(r’^$’,line.strip()):
    lines.append(line.strip())
    return lines

    def returnControllerNumber(output):
    for line in output:
    if re.match(r’^Controller Count.*$’,line.strip()):
    return int(line.split(‘:’)[1].strip().strip(‘.’))

    def returnControllerModel(output):
    for line in output:
    if re.match(r’^Product Name.*$’,line.strip()):
    return line.split(‘:’)[1].strip()

    def returnArrayNumber(output):
    i = 0
    for line in output:
    if re.match(r’^Virtual (Drive|Disk).*$’,line.strip()):
    i += 1
    return i

    def returnArrayInfo(output,controllerid,arrayid):
    id = ‘c’+str(controllerid)+’u’+str(arrayid)
    # print ‘DEBUG: id = ‘+str(id)
    operationlinennumber = False
    linenumber = 0
    units = 1
    type = ‘JBOD’
    span = 0
    size = 0
    for line in output:
    if re.match(r’^RAID Level.*$’,line.strip()):
    type = line.strip().split(‘:’)[1].strip()
    type = ‘RAID’ + type.split(‘,’)[0].split(‘-‘)[1].strip()
    # print ‘debug: type = ‘+str(type)
    if re.match(r’^Number.*$’,line.strip()):
    units = line.strip().split(‘:’)[1].strip()
    if re.match(r’^Span Depth.*$’,line.strip()):
    span = line.strip().split(‘:’)[1].strip()
    if re.match(r’^Size.*$’,line.strip()):
    # Size reported in MB
    if re.match(r’^.*MB$’,line.strip().split(‘:’)[1]):
    size = line.strip().split(‘:’)[1].strip(‘MB’).strip()
    size = str(int(round((float(size) / 1000))))+’G’
    # Size reported in TB
    elif re.match(r’^.*TB$’,line.strip().split(‘:’)[1]):
    size = line.strip().split(‘:’)[1].strip(‘TB’).strip()
    size = str(int(round((float(size) * 1000))))+’G’
    # Size reported in GB (default)
    else:
    size = line.strip().split(‘:’)[1].strip(‘GB’).strip()
    size = str(int(round((float(size)))))+’G’
    if re.match(r’^State.*$’,line.strip()):
    state = line.strip().split(‘:’)[1].strip()
    if re.match(r’^Ongoing Progresses.*$’,line.strip()):
    operationlinennumber = linenumber
    linenumber += 1
    if operationlinennumber:
    inprogress = output[operationlinennumber+1]
    else:
    inprogress = ‘None’
    if span > 1:
    type = type+’0′
    type = type + ‘ ‘ + str(span) + ‘x’ + str(units)
    return [id,type,size,state,inprogress]

    def returnDiskInfo(output,controllerid,currentarrayid):
    arrayid = False
    oldarrayid = False
    olddiskid = False
    table = []
    state = ‘Offline’
    model = ‘Unknown’
    enclnum = ‘Unknown’
    slotnum = ‘Unknown’
    enclsl = ‘Unknown’

    firstDisk = True
    for line in output:
    if re.match(r’Firmware state: .*$’,line.strip()):
    state = line.split(‘:’)[1].strip()
    if re.match(r’Rebuild’,state):
    cmd2 = ‘/opt/MegaRAID/MegaCli/MegaCli64 pdrbld showprog physdrv[‘+str(enclnum)+’:’+str(slotnum)+’] a’+str(controllerid)+’ nolog’
    ll = getOutput(cmd2)
    state += ‘ completed ‘ + re.sub(r’Rebuild Progress.*Completed’, ”, ll[0]).strip();
    if re.match(r’Slot Number: .*$’,line.strip()):
    slotnum = line.split(‘:’)[1].strip()
    if re.match(r’Inquiry Data: .*$’,line.strip()):
    model = line.split(‘:’)[1].strip()
    model = re.sub(‘ +’, ‘ ‘, model)
    model = re.sub(‘Hotspare Information’, ”, model).strip() #remove bogus output from firmware 12.12
    if re.match(r”(Drive|Disk)’s postion: .*$”,line.strip()):
    spans = line.split(‘,’)
    span = re.sub(r”(Drive|Disk).*DiskGroup:”, ”, spans[0]).strip()+’-‘
    span += spans[1].split(‘:’)[1].strip()+’-‘
    span += spans[2].split(‘:’)[1].strip()
    if re.match(r’Enclosure Device ID: [0-9]+$’,line.strip()):
    if firstDisk == True:
    firstDisk = False
    else:
    enclsl = str(enclnum)+’:’+str(slotnum)
    table.append([str(enclsl), span, model, state])
    span = ‘x-x-x’
    enclnum = line.split(‘:’)[1].strip()
    # Last disk of last array
    enclsl = str(enclnum)+’:’+str(slotnum)
    table.append([str(enclsl), span, model, state])
    arraytable = []
    for disk in table:
    arraytable.append(disk)
    return arraytable

    cmd = ‘/opt/MegaRAID/MegaCli/MegaCli64 adpcount nolog’
    output = getOutput(cmd)
    controllernumber = returnControllerNumber(output)

    bad = False

    # List available controller if printcontroller:
    print ‘– Controllers –‘
    print ‘– ID | Model’
    controllerid = 0
    while controllerid < controllernumber: cmd = '/opt/MegaRAID/MegaCli/MegaCli64 adpallinfo a'+str(controllerid)+' nolog' output = getOutput(cmd) controllermodel = returnControllerModel(output) print 'c'+str(controllerid)+' | '+controllermodel controllerid += 1 print '' if printarray: controllerid = 0 print ‘– Volumes –‘ print ‘– ID | Type | Size | Status | InProgress’ # print ‘controller number’+str(controllernumber) while controllerid < controllernumber: arrayid = 0 cmd = '/opt/MegaRAID/MegaCli/MegaCli64 ldinfo lall a'+str(controllerid)+' nolog' output = getOutput(cmd) arraynumber = returnArrayNumber(output) # print 'array number'+str(arraynumber) while arrayid < arraynumber: cmd = '/opt/MegaRAID/MegaCli/MegaCli64 ldinfo l'+str(arrayid)+' a'+str(controllerid)+' nolog' # print 'DEBUG: running '+str(cmd) output = getOutput(cmd) # print 'DEBUG: output '+str(output) arrayinfo = returnArrayInfo(output,controllerid,arrayid) print 'volume '+arrayinfo[0]+' | '+arrayinfo[1]+' | '+arrayinfo[2]+' | '+arrayinfo[3]+' | '+arrayinfo[4] if not arrayinfo[3] == 'Optimal': bad = True arrayid += 1 controllerid += 1 print '' print ‘– Disks –‘ print ‘– Encl:Slot | vol-span-unit | Model | Status’ controllerid = 0 while controllerid < controllernumber: arrayid = 0 cmd = '/opt/MegaRAID/MegaCli/MegaCli64 ldinfo lall a'+str(controllerid)+' nolog' output = getOutput(cmd) arraynumber = returnArrayNumber(output) while arrayidjohnpuskar@gmail.com on 08/14/11
    # rev 01

    import os import re import sys

    if len(sys.argv) > 1:
    print ‘Usage: accepts stdin from lsi-raidinfo’
    sys.exit(1)

    blnBadDisk = False infile = sys.stdin for line in infile:
    # print ‘DEBUG!! checking line:’+str(line)
    if re.match(r’disk .*$’,line.strip()):
    if re.match(r’^((?!Online, Spun Up|Online, Spun down|Hotspare, Spun Up|Hotspare, Spun down|Unconfigured\(good\), Spun Up).)*$’,line.strip()):
    blnBadDisk = True
    badLine = line
    # print ‘DEBUG!! bad disk found!’
    if re.match(r’volume ‘,line.strip()):
    if re.match(r’^((?!Optimal).)*$’,line.strip()):
    # print ‘DEBUG!! bad vol found!’
    blnBadDisk = True
    badLine = line

    if blnBadDisk == True:
    print ‘RAID ERROR’
    # print badLine else:
    print ‘RAID CLEAN’

    ======EOF======

    and finally, this is bin/lsi-emailalerts, which uses the above to send an email alert…

    #!/bin/sh

    MAILTOADDR=root HOST=$(hostname -s| tr [a-z] [A-Z])

    #get megaraid status info
    /root/bin/lsi-raidinfo | tee /tmp/lsi-raidinfo.txt |
    /root/bin/lsi-checkraid > /tmp/lsi-checkraid.txt

    #check megaraid status info if grep -qE “RAID ERROR” /tmp/lsi-checkraid.txt ; then
    cat /tmp/lsi-raidinfo.txt | mailx -s “$HOST Warning: failed disk or degraded array” $MAILTOADDR
    fi

    #check mpt status

    if (bin/mpt-status -s | awk ‘{print $3}’ | egrep -qv
    “(OPTIMAL|ONLINE)”) ; then
    bin/mpt-status | mailx -s “$HOST Warning: internal disk failure” $MAILTOADDR
    fi

    #rm -f /tmp/lsi-raidinfo.txt
    #rm -f /tmp/lsi-checkraid.txt exit 0